Op Amp Error Budget: Worst Case, RSS & Monte Carlo | Lab 4

Can 1,000 Monte Carlo runs prove an amplifier meets a ±5 mV limit?
The sensor’s error limit works out to ±31 counts at the ADC. Testing all 64 tolerance corners exposes extreme combinations, and changing the assumed part distribution changes how often random draws miss the limit. Those two results answer different design questions.
What you’ll work with
- An error-budget spreadsheet and LTspice circuits.
- A tolerance-allocation exercise for two sensor endpoints.